Evolution Aqua Varipump

Evolution Aqua Varipump

 

 

 

 

 

 

High performance controllable pond pumps

 

Varipump by Evolution Aqua is a controllable pond pump, suitable for large ponds.
Output and energy consumption can be controlled at the push of a button allowing you to set the flow rate to your needs, whilst monitoring the wattage that the pump is running at. The motor is quiet and reliable, delivering consistent performance.

Available in three sizes, 10,000lph, 20,000lph and 30,000lph.

Varipump is powerful enough to run the largest of ponds and filters, and in the most demanding of situations.
It can be used as a submersible pond pump or it can be installed out of the pond, drawing water from the pond and through your filtration system. 

Hosetail fittings are included.

 

 

 

VariPump

 

 

Specifications

 

 Inlet/ Outlet

Max. Flow

(Litres Per Hour)

Max. Flow

(Gallons Per Hour)

Max. Flow

(US Gallons Per Hour)

Max. HeadMax. Watts
Varipump 100001½"10,000 lph2,200 gph2,640 US gph5.5m90w
Varipump 200002"20,000 lph4,400 gph5,280 US gph6.5m190w
Varipump 300002"30,000 lph6,600 gph7,925 US gph6.5m290w

 

Dimensions

 

MODEL DIMENSIONS CABLE LENGTHS:

 

2 metre cable from plug to control box
10 metre cable from pump to control box 

 

Varipump 10000 267mm (L) x 122mm (W) x 162mm (H)

Varipump 20000 319mm (L) x 142mm (W) x 181mm (H) 

Varipump 30000 370mm (L) x 155mm (W) x 205mm (H)

 

 

variPump Dimensions

 

 

variPump Curves

 

INSTALLING THE VARIPUMP

 

Varipump can be installed either dry, as part of a gravity fed filtration system, or submersed in water, as part of a pump fed system. When installing in gravity fed systems ensure unions are fitted (not supplied) to enable removal of the pump for cleaning and maintenance. We recommend using 1.5" threaded unions for the 10,000 model. Use 2" threaded unions for the 20,000 and 30,000 models.

 

INSTALLING THE VARIPUMP - GRAVITY FED

 

1.  The pump suction line should be not smaller than 1½” (40mm imperial) or 50mm true metric.

2.  The suction line is to have as few bends or elbows as possible. There must not be an air trap on the suction line.

3.  Tighten the pump fittings only as much as is required to ensure a tight connection. Excessive torque is unnecessary and may cause damage to the pump.

4.  All wiring (electrical) work must be carried out by qualified electricians and must be installed in accordance to the local codes.

5.  The motor must be earthed.

6.  The weight of the plumbing and fittings is to be independently supported and not carried by the pump.

7.  The pump is not self-priming. Therefore, if the water level is below the pump, a non-return valve must be installed below water level. The pump and inlet line must be primed prior to start up. For non-flooded installations a check valve (non-return valve) is recommended.

8.  The controller must not be submerged in water.

 

INSTALLING THE VARIPUMP - PUMP FED

 

Varipump can be submersed in water, as part of a pump fed system. When installing on pump fed systems ensure we recommend using the hosetails provided to connect up to flexible hose (not supplied).

 

1.  Flexible hose (not supplied) should be the widest possible diameter.

2.  Extra steps on hosetails should always be sawn off and removed.

3.  A hoseclip (not supplied) must always be used to hold the hose in place on the hosetail.

4.  Ensure sealing rings are fitted properly.

5.  All wiring (electrical) work must be carried out by qualified electricians and must be installed in accordance to the local codes.

6.  The motor must be earthed.

7.  Do not let the pump run dry.

8.  The controller must not be submerged in water

 

Authors
Archive
Leave a comment
Your email address will not be visible